MN Oftalmoloji

MN Oftalmoloji Cilt: 31 Sayı: 1 2024 (MN Ophthalmology Volume: 31 No: 1 2024)

Katarakt Cerrahisi Öncesi Bir Gün Kullanılan %0,1 Nepafenak’ın Oküler Biyometri Parametreleri ve Göz İçi Lens Gücü Hesaplama Formüllerine Etkisi

The Effect of One-Day Topical Use of 0.1% Nepafenac on Ocular Biometry Parameters and Intraocular Lens Power Calculation Formulas

Oğuzhan ORUZ, Mustafa EROĞLU, Mehmet Serdar DERVİŞOĞULLARI, Eylem GÜL ATEŞ


Öz

Amaç: Ameliyat öncesi bir gün süreyle topikal %0.1 nepafenak göz damlasının oküler biyometri parametreleri üzerindeki etkilerini araştırmak.

Gereç ve Yöntem: Çalışmaya 50 hastanın 50 gözü dahil edildi. Hastaların yaş ortalaması 67.79±9.87 idi. Çalışma Nisan 2022-Aralık 2022 tarihleri arasında gerçekleştirildi. Topikal nepafenak %0.1 göze damla damlatıldıktan sonra göz içi lens (GİL) gücü Sanders/Retzlaff/Kraff Theoretical, Holladay, Hoffer Q ve Haigis formülleri ile belirlendi.

Bulgular: İlaç tedavisi sonrası ön kamara derinliğinin istatistiksel anlamlı olarak azaldığı saptandı (p=0,02). Diğer biyometrik parametrelerde istatistiksel olarak anlamlı bir değişiklik saptanmadı (tümü için p>0,05). İlaç öncesi ve sonrası üçüncü ve dördüncü kuşak formüllerle yapılan GİL güç hesaplamaları arasında fark yoktu (tümü için p>0,05).

Sonuç: Topikal %0,1 nepafenak kullanıldıktan sonra ön kamara derinliği değişmesine rağmen ilaç öncesi ve sonrası GİL güç ölçümlerinde fark yoktu.

Anahtar Kelimeler: Biyometri, Katarakt cerrahisi, Nepafenak, Refraksiyon, Topikal NSAİD’ler

Abstract

Objective: To investigate the effects of topical nepafenac 0.1% eye drops for one day preoperatively on ocular biometry parameters.

Material and Method: Fifty eyes of 50 patients were analyzed in the study. The mean age of the patients was 67.79±9.87, and their ages ranged between 39 and 95 .The study was carried out for nine months between April and December 2022. In all patients, intraocular lens power was calculated with the IOLMaster 500 device before and after topical nepafenac 0.1% eye drop instillation. The intraocular lens power was determined through Sanders/Retzlaff/Kraff Theoretical, Holladay, Hoffer Q, and Haigis formulas.

Results: Anterior chamber depth significantly decreased after medication (p=0.02). There were no statistically significant changes detected in other biometrics parameters (p>0.05 for all). There were no differences between the IOL power calculations made with the third and fourth-generation formulas before and after medications (p>0.05 for all).

Conclusion: Although the anterior chamber depth changed after using topical Nepafenac 0.1%, there were no differences in pre- and post-medication IOL power measurements.

Keywords: Biometry, Cataract Surgery, Nepafenac, Refraction, Topical NSAIIDs


Gizlilik Beyanı

Yazarlar, MN Oftalmoloji dergisi tarafından yukarıda istenen bilgileri sisteme yüklemeyi kabul ederler. MN Oftalmoloji, kişisel bilgilerinizin gizliliği ve güvenliğini koruyacaktır. Herhangi bir kişisel bilgi sadece bu dergi ve bilimsel amaçlar için kullanılacaktır. Bu bilgiler başka amaçlarla kullanılmayacak ve üçüncü taraflarla paylaşılmayacaktır. Tek istisna, mahkeme kararları, taleplere karşı savunma hakları, yasadışı faaliyetlerden korunma ve benzeri yasal durumlardır.

Yazarlar; dergideki yenilikler, sağlık dünyasındaki gelişmeler, kongreler, sempozyumlar, toplantılar, seminerler ve farmakolojik gelişmeler hakkında MN Oftalmoloji dergisinden gönderilecek yazılı, sözlü ve görsel bilgilendirme e-postası almayı kabul eder.